{"id":626,"date":"2026-11-03T11:16:07","date_gmt":"2026-11-03T03:16:07","guid":{"rendered":"http:\/\/www.bolgehaberleri.com\/blog\/?p=626"},"modified":"2026-11-03T11:16:07","modified_gmt":"2026-11-03T03:16:07","slug":"how-to-measure-the-leakage-of-an-air-preheater-seal-43ec-7ee8e8","status":"publish","type":"post","link":"http:\/\/www.bolgehaberleri.com\/blog\/2026\/11\/03\/how-to-measure-the-leakage-of-an-air-preheater-seal-43ec-7ee8e8\/","title":{"rendered":"How to measure the leakage of an air preheater seal?"},"content":{"rendered":"<p>Hey everyone, if you\u2019re in the power generation, cement, or steel industries, you know air preheaters (APH) are non-negotiable\u2014they recycle waste heat from flue gases to heat combustion air, which cranks up efficiency and cuts fuel costs. But here\u2019s the deal: if your APH\u2019s seals are leaking, all that efficiency goes out the window. As someone who\u2019s been in the air preheater seal supply game for over a decade, I\u2019ve heard way too many plant ops scratch their heads trying to figure out how to actually measure that leakage\u2014half the time they\u2019re guessing, and the other half they\u2019re using methods that are either super time-consuming or just plain wrong. Today, I\u2019m breaking down the practical, science-backed ways to measure APH seal leakage, no fancy jargon required. <a href=\"https:\/\/www.cnturbine.com\/air-preheater-seal\/\">Air Preheater Seal<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.cnturbine.com\/uploads\/47617\/page\/small\/segmented-carbon-ring-sealb6559.jpg\"><\/p>\n<p>First, let\u2019s get on the same page about what APH seal leakage even is. Most large APHs are either rotary (the most common) or fixed, but we\u2019re gonna focus on rotary ones \u2019cause that\u2019s where 90% of the seal issues happen. Rotary APHs have a rotating rotor with heat-exchange elements, and seals are between the rotor and the stationary casing to stop hot flue gas (on one side) and cold combustion air (on the other) from mixing. Leakage is just the amount of that cross-flow\u2014if it\u2019s too high, you\u2019re wasting fuel, reducing boiler output, and even risking damage from uneven heating. The goal is keeping it under 10-15% for most utility APHs, right?<\/p>\n<p>Now, the first method almost every plant uses: Air Flow Differential Test. It\u2019s straightforward, no fancy tools, just your existing plant instruments. Here\u2019s how it works: You measure the air flow on the cold side (the combustion air going into the APH) and the flue gas flow on the hot side (coming out of the APH). But wait, it\u2019s not just raw flow numbers\u2014you have to adjust for temperature and pressure, \u2019cause gas density changes with those. Let me make it simple: say your induced draft (ID) fan pulls flue gas at 300\u00b0F, and your forced draft (FD) fan pushes air at 100\u00b0F. Use the ideal gas law to correct both flows to standard conditions, then calculate the difference. If flue gas flow is way less than you expected compared to air flow, that\u2019s the leakage. I\u2019ve seen guys mess this up by not correcting for density\u2014like, last year a plant told me their leakage was 18%, but after fixing the temp\/pressure correction, it dropped to 9%. That\u2019s the thing: this method is quick, takes 15 minutes with existing tools, but it\u2019s indirect. It measures total leakage, not which seal (radial, axial, circumferential) is bad. Good for a quick check, but not for troubleshooting.<\/p>\n<p>Next, the method we rely on every day for our customers: Gas Concentration Tracer Test. This is way more accurate, and tells you exactly how much leakage is coming from the seals, not other gaps. The idea is: inject a harmless tracer gas\u2014usually sulfur hexafluoride (SF6) \u2019cause it\u2019s heavy, easy to detect, and doesn\u2019t react with flue gases\u2014into the cold air side of the APH. Then you sample the hot flue gas side, measure how much SF6 is there. Since SF6 shouldn\u2019t be in flue gas otherwise, the amount you find is directly from seal leakage. Let\u2019s do a quick math example: if you inject 100 liters of SF6 into the air side, and sample 5 liters in the flue side, leakage is 5%\u2014that\u2019s simple. The trick here is where you inject and sample. Don\u2019t dump the SF6 right at the FD fan inlet\u2014put it in the main air duct just before it hits the APH. For samples, take multiple points across the flue duct, not just one spot, \u2019cause gas mixes unevenly. I always tell my customers to use a portable SF6 detector\u2014they run like $2k, but way cheaper than shutting down a plant for a week to replace seals unnecessarily. The downside? It takes a bit more prep, and you can\u2019t run this test if the APH is off (obviously) or if there\u2019s too much draft messing with gas flow. But when you need exact numbers, this is the gold standard.<\/p>\n<p>Wait, there\u2019s another one for older plants or if you can\u2019t get a tracer gas: Pressure Drop Test. This is super basic, but a lot of people forget it. Rotary APHs have different pressure zones: the cold air side is at a higher pressure than the hot flue side (that\u2019s how the flow works, duh). Seals are supposed to maintain a tight barrier between these two pressures. If you measure the pressure difference across each seal section\u2014radial (between rotor and casing sides), axial (between rotor top\/bottom and casing), circumferential (between rotor diameter and casing)\u2014low pressure difference means a leaky seal. For example, a good radial seal should have a 1-2 inch water column (inH2O) pressure drop; if it\u2019s less than 0.5 inH2O, that seal\u2019s blown. The key here is to do this when the APH is at operating load\u2014idle mode pressure is way different. I once worked with a plant that thought their radial seals were fine, but a pressure test showed circumferential seals were leaking bad, which we fixed, and their fuel use dropped 8%. It\u2019s free, uses a manometer you probably already have, but again, it\u2019s indirect\u2014can\u2019t tell total leakage, just pressure gaps.<\/p>\n<p>Now, let\u2019s talk about common mistakes people make when measuring, \u2019cause that\u2019s where most of the bad data comes from. First, testing at low load. APHs move differently when they\u2019re running at 50% load vs 100%\u2014the rotor expands or contracts, seals might rub or gap. If you test at half load, your numbers are off, so you end up replacing seals that don\u2019t need it, or missing a leak that\u2019s bad at full load. Second, ignoring temperature drift. The ideal gas law? If you don\u2019t account for flue gas getting hotter, your flow numbers are wrong. Third, bad sampling for tracer tests. If you sample only near the duct wall, you might miss the SF6 that\u2019s mixing in the center, so you underestimate leakage. And fourth, skipping pre-test checks. Like, make sure the APH\u2019s inspection doors are closed, no gaps in the casing\u2014if air is leaking through a loose door, that\u2019s not seal leakage, it\u2019s a casing gap. I once had a customer who spent 3 hours doing a tracer test, only to find a door was ajar\u2014we fixed that door, and leakage dropped 2 points right away.<\/p>\n<p>Also, pro tip: combine two methods for best results. Do a quick air flow differential first to get a rough number, then a tracer test to confirm and find which seal is bad. If you see high leakage from the tracer test, and the pressure test shows radial seals have low pressure drop, you know exactly which seals to replace, not all of them. That saves you time and money\u2014no need to rip out every seal, just the bad ones.<\/p>\n<p>Wait, let\u2019s also mention what\u2019s considered \u201cnormal\u201d leakage, so you know when you need to act. For a new rotary APH, leakage should be 5-10%. For older ones, up to 15% is manageable, but anything over 20%? That\u2019s costing you real cash. I\u2019ve done calculations for a 500MW plant\u2014if leakage goes from 15% to 25%, they\u2019re burning an extra $50k in fuel every month. That\u2019s why measuring leakage isn\u2019t just a check, it\u2019s a cost-saver.<\/p>\n<p>Now, if you\u2019re reading this and thinking \u201cyeah, my APH\u2019s been running weird, maybe I need help measuring or fixing seals\u201d\u2014that\u2019s what we do. We supply custom APH seals, and we work with plant ops to measure leakage accurately, no guesswork. If you\u2019re tired of inefficient fuel use, or you replaced seals before and they didn\u2019t fix the leak, hit us up. We can come out with our portable tracer test gear, do a full scan, tell you exactly what\u2019s wrong, and get you the right seals to fix it.<\/p>\n<p>Before I wrap up, let\u2019s hit the basics again to make sure you don\u2019t forget: 1) Air Flow Differential = quick, indirect, good for initial check; 2) SF6 Tracer Test = accurate, identifies which seal is leaking, gold standard for precision; 3) Pressure Drop Test = free, uses existing tools, good for troubleshooting. And always test at full load, close all casing gaps, and combine methods for the best data.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.cnturbine.com\/uploads\/47617\/page\/small\/rear-cylinder-seal6445b.jpg\"><\/p>\n<p>If you have questions, or you need help measuring your APH\u2019s leakage, don\u2019t hesitate to reach out. We\u2019re here to make sure you\u2019re not wasting fuel or money on unnecessary repairs.<\/p>\n<p><a href=\"https:\/\/www.cnturbine.com\/air-preheater-seal\/\">Air Preheater Seal<\/a> References<\/p>\n<ol>\n<li>Power Plant Air Preheater Performance Test Code, American Society of Mechanical Engineers (ASME PTC 4.3-2014)<\/li>\n<li>Rotary Air Preheater Seal Leakage Mitigation, International Society of Automation (ISA)<\/li>\n<li>Industrial Boilers and Heat Recovery Steam Generators: Design, Applications, and Calculations, CRC Press<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.cnturbine.com\/\">Jiangsu Turbine Electric Power Technology Co., Ltd.<\/a><br \/>As one of the most professional air preheater seal manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. Please feel free to buy advanced air preheater seal for sale here and get pricelist from our factory. Customized orders are welcome.<br \/>Address: Building 8, Huaqi Yungu Xuzhou Lingang Industry Accelerator, Jiawang District, Xuzhou City, Jiangsu Province<br \/>E-mail: zjh800@163.com<br \/>WebSite: <a href=\"https:\/\/www.cnturbine.com\/\">https:\/\/www.cnturbine.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hey everyone, if you\u2019re in the power generation, cement, or steel industries, you know air preheaters &hellip; <a title=\"How to measure the leakage of an air preheater seal?\" class=\"hm-read-more\" href=\"http:\/\/www.bolgehaberleri.com\/blog\/2026\/11\/03\/how-to-measure-the-leakage-of-an-air-preheater-seal-43ec-7ee8e8\/\"><span class=\"screen-reader-text\">How to measure the leakage of an air preheater seal?<\/span>Read more<\/a><\/p>\n","protected":false},"author":48,"featured_media":626,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[589],"class_list":["post-626","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-air-preheater-seal-4f9d-80505b"],"_links":{"self":[{"href":"http:\/\/www.bolgehaberleri.com\/blog\/wp-json\/wp\/v2\/posts\/626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.bolgehaberleri.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.bolgehaberleri.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.bolgehaberleri.com\/blog\/wp-json\/wp\/v2\/users\/48"}],"replies":[{"embeddable":true,"href":"http:\/\/www.bolgehaberleri.com\/blog\/wp-json\/wp\/v2\/comments?post=626"}],"version-history":[{"count":0,"href":"http:\/\/www.bolgehaberleri.com\/blog\/wp-json\/wp\/v2\/posts\/626\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.bolgehaberleri.com\/blog\/wp-json\/wp\/v2\/posts\/626"}],"wp:attachment":[{"href":"http:\/\/www.bolgehaberleri.com\/blog\/wp-json\/wp\/v2\/media?parent=626"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.bolgehaberleri.com\/blog\/wp-json\/wp\/v2\/categories?post=626"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.bolgehaberleri.com\/blog\/wp-json\/wp\/v2\/tags?post=626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}