Hey there, fellow industrial folks! Let’s cut to the chase for a sec—auxiliary equipment is like the unsung hero of any manufacturing, processing, or even heavy-duty operation. You might have a top-of-the-line main machine, but if your pumps, compressors, motors, or those random bits of kit that keep things running are dragging their feet, you’re leaving money on the table. As someone who’s been deep in the auxiliary equipment game for years (yep, I’m the guy that helps shops pick, tweak, and fix these behind-the-scenes workhorses), I get it—efficiency isn’t just a buzzword here. It’s how you keep your costs down and your output steady. But how do you actually measure that? No boring textbook stuff, let’s make this real. Auxiliary Equipments

First off, let’s clarify what we’re even talking about here. Auxiliary equipment (we’ll call it aux gear for short, since we’re all in a hurry) is all the stuff that supports your main production line without being the star. Think water pumps for cooling systems, air compressors for pneumatic tools, transformers for power distribution, conveyor systems for moving parts, and even the small fans that keep your electrical cabinets from overheating. The problem is, a lot of operators just check if it’s “running” instead of how well it’s running. That’s where measuring efficiency comes in—because a pump that’s making noise and using way more electricity than it should isn’t just inefficient, it’s a hidden drain on your bottom line.
Let’s start with the basics: the two big metrics you can’t skip. I see too many companies guessing here, and it drives me nuts. First is energy efficiency—this is the big one for most shops, since energy costs are only going up. Second is operational efficiency, which is how well the aux gear actually does the job it’s supposed to, not just how much power it uses. Let’s break these down so you don’t need a PhD in engineering to follow.
For energy efficiency, let’s take two super common examples: air compressors and electric motors. These are the aux gear that suck up more energy than any other in most facilities, so they’re the easiest place to start. First, don’t just rely on the numbers your machine’s display says. Those displays are often rounded up, or not calibrated right. Grab a power meter—they’re cheap, easy to use, and way more accurate. For a motor, here’s what you do: measure the actual power it’s drawing (in kW) while it’s running at full load, then compare that to its rated power (the number on the nameplate). If it’s drawing 20% more power than the nameplate says it should, that’s a red flag. That means it’s working harder than it needs to, wasting energy.
Wait, what about the work it’s doing? A compressor isn’t just supposed to use power—it’s supposed to deliver a consistent volume of air (in CFM, cubic feet per minute) at the right pressure (PSI). So energy efficiency here isn’t just kW used—it’s CFM per kW. If your compressor is delivering 100 CFM but using 15 kW, and the model next door delivers 100 CFM using 12 kW, yours is 20% less efficient. That’s the kind of number that shows up on your utility bill every month. I had a client last quarter who was running two old compressors that were at 75 CFM/kW; we swapped in a modern aux gear set, and they jumped to 110 CFM/kW. Their energy bill for that part of the plant dropped by $1,200 a month. That’s real money, not just math.
Then there’s thermal efficiency, which is huge for cooling aux gear like pumps and chillers. Let’s say you have a water pump for your main machine’s cooling system. Its job is to move water from the chiller to the main machine and back, right? So thermal efficiency here is how well it’s moving heat away. To measure that, you take the temperature of the water going into the main machine and coming out. If the in temp is 45°F and the out is 55°F, that’s a 10°F heat transfer. If the pump is drawing too much power but the temp difference is only 3°F, something’s off—either the impeller is worn, or the system has leaks that are making it work harder. A lot of guys miss this because they only check if water is flowing, not how well it’s doing the job of cooling. That’s a mistake I see all the time.
Now, operational efficiency—this is the part that’s not just about power, but about uptime and consistency. Your aux gear might be using the right amount of power, but if it’s breaking down every other week, that’s zero efficiency. Let’s define operational efficiency simply: it’s the amount of good output you get from the aux gear compared to its maximum potential, minus downtime. For example, a conveyor system for moving raw materials to your main line. If it’s supposed to move 10 tons an hour, but it only does 7 tons an hour because of frequent jams, that’s low operational efficiency. Also, downtime counts: if it’s down for 10 hours a month for repairs, that’s time your main line can’t run, so that’s a hit too.
How do you measure operational efficiency? Start with availability: that’s (total time the equipment is supposed to run minus downtime) divided by total time. So if your conveyor runs 700 hours a month, and downtime is 50 hours, availability is (650/700) = 92.8%. Then there’s performance: that’s (actual output / maximum rated output) times 100. If maximum output is 10 tons an hour, and actual is 7, performance is 70%. Then operational efficiency is availability times performance. So 92.8% x 70% = 64.9%. That means only about two-thirds of the time, your conveyor is actually contributing to production, not sitting around or underperforming. I worked with a metal fabrication shop last year that had a 50-foot conveyor with constant jams. We adjusted the rollers and added a small sensor to catch misaligned parts, and their operational efficiency jumped to 88% in a week. They saw a 15% increase in production from that one small tweak.
Wait, let’s not forget about wear and tear efficiency. A lot of aux gear wears out over time, and that directly hits efficiency. For example, a pump with a worn impeller doesn’t move as much water, so you have to run it faster, which uses more energy. Or a compressor with a clogged air filter has to work harder to pull in air, wasting power. How do you measure this? Track the rate of wear over time. Check the impeller every few months for pitting, measure air filter pressure drop (if it’s higher than the manufacturer’s recommended limit, that’s a sign it’s clogged), and check for vibration—too much vibration usually means worn bearings or misaligned parts. I tell my clients to do a quick “vibration check” once a week with a $20 sensor you can get on Amazon. It takes 2 minutes, and if the vibration is above a certain threshold, you know to fix it before it gets worse. That’s way cheaper than waiting for the pump to break and shutting down your main line.
Now, let’s talk about common mistakes I see when measuring aux gear efficiency. First, using generic benchmarks instead of your own. Every facility is different—your compressor’s efficiency number shouldn’t match the one in a factory 100 miles away because your air line is longer, or your pressure needs are different. Second, only measuring efficiency when the equipment is brand new. Efficiency drops over time, so you need to measure it regularly—quarterly is a good rule, and after any maintenance or repair, too. Third, ignoring small aux gear. The little fans for electrical cabinets, the small pumps for hydraulic systems—these add up. A 10% inefficiency on 5 small motors is the same as a 10% inefficiency on one big one, but no one checks the small ones. I had a client who didn’t even know their control panel fan was broken for 6 months. That overheated their PLC, and they had to shut down for 3 days to fix it. The cost of that shutdown was 10x more than the cost of the fan and a few efficiency checks.
So once you measure efficiency, what do you do with the numbers? If you find your aux gear is underperforming, you have three options: repair, replace, or adjust operations. Let’s say your old air compressor is 25% less efficient than a new model. If the repair costs $2,000, but a new one is $10,000, and you’ll save $1,500 a month on energy, then the new one is a no-brainer. But if it’s just a clogged filter and a misaligned belt, a $50 filter and a 10-minute adjustment will fix it, no need to replace. Sometimes adjusting operations helps too—like running your compressors at off-peak times when electricity is cheaper, or staggering your aux gear use so you’re not pulling too much power at once. That’s called demand side management, and it can cut energy costs by another 10-15% without buying new gear.
Here’s the thing I always tell my clients: measuring aux gear efficiency isn’t a one-time task. It’s a habit. The shops that are making the most profit are the ones that track these numbers, tweak their aux gear regularly, and don’t let the small stuff add up. I’ve been in this game for 12 years, and the best advice I can give is stop treating aux gear like afterthoughts. They’re not just “stuff that runs in the background”—they’re a big part of your bottom line.
If you’re not sure where to start, don’t overcomplicate it. Grab a power meter for your biggest aux gear (motor, compressor, pump), track its kW and output for a week, and compare it to the manufacturer’s specs. If you can’t find the specs, or the numbers don’t add up, reach out. I’ve helped hundreds of shops sort through their aux gear efficiency, and we can do the same for you. Whether you need a quick efficiency audit, a recommendation for a new aux gear set, or help tweaking your existing equipment, we’re here to make sure you’re not wasting money on gear that’s working harder than it should.

Wait, let’s wrap this up so it flows naturally, no awkward ending. To sum up: measuring auxiliary equipment efficiency is simple when you focus on two core areas—energy efficiency (kW per unit output) and operational efficiency (uptime plus actual output vs. potential). Skip the fancy stuff at first, use affordable tools, check regularly, and don’t ignore the small gear. The money you save on energy and downtime will way outweigh the time you spend measuring. If you’re ready to stop guessing and start seeing real numbers for your aux gear, get in touch to chat about your specific operation. We can walk through your setup, point out where you’re leaking efficiency, and give you clear steps to fix it.
Four Station Thermoforming Machine References:
- Industrial Auxiliary Equipment Efficiency Guidelines, U.S. Department of Energy, 2022
- “Measuring Operational Efficiency for Industrial Support Systems,” Journal of Manufacturing Engineering, Vol. 18, No. 3, 2021
- Vibration Analysis for Auxiliary Equipment Maintenance, International Society of Automation, 2020
- Energy Management for Small to Medium Industrial Facilities, National Institute of Standards and Technology, 2023
Zhejiang Sayeah Machinery Co., Ltd.
Zhejiang Sayeah Machinery Co., Ltd. is one of the most reliable manufacturers and suppliers of auxiliary equipments in China, also supports high quality customized service. Please feel free to buy CE approved auxiliary equipments from our factory. For price consultation, contact us.
Address: Wanquan District Industrial Zone,West Of China National Highway 104, Sunlou Village, Wanquan Town, Pingyang County, Zhejiang Province. China
E-mail: sales@sayeahmachinery.com
WebSite: https://www.sayeahthermoforming.com/